65. Measuring ToolsThickness IndicatorsThickness Gauges Magnetic Coating

Thickness Gauges Magnetic Coating

652721 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 5/6 G
652721 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 5/6 G
IMPA:652721
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652722 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 5/6 F
652722 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 5/6 F
IMPA:652722
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652723 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S3
652723 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S3
IMPA:652723
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652724 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S5
652724 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S5
IMPA:652724
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652725 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S10
652725 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S10
IMPA:652725
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652726 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S20
652726 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 S20
IMPA:652726
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652727 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NI50
652727 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NI50
IMPA:652727
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652728 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NI100
652728 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NI100
IMPA:652728
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.
652729 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NIFE50
652729 COATING THICKNESS GAUGE, MAGNETIC MIKROTEST 6 NIFE50
IMPA:652729
MTML UOM:PCE
Non-destructive thickness measurement of non-magnetic coatings, e.g.: zinc, copper, chrome, cadmium, etc. Also paint enamel, plastic, etc. on iron and steel. The measurement of film thickness depends on the degree of magnetic attraction to a surface. The attraction depends on the distance of a permanent magnet from a steel surface. This distance represents the thickness of a non-magnetic coating. No power supply or calibration necessary. Operating temperature –20oC to 100oC.