Bump Test and Calibration Station
330604 BUMPTEST & CALIBRATION STATION, GALAXY GX2 NO-CHARGE #10128651
IMPA:330604
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330605 BUMPTEST & CALIBRATION STATION, GALAXY GX2 NO-CHARGE #10128637
IMPA:330605
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330606 BUMPTEST & CALIBRATION STATION, GALAXY GX2 CHARGING #10128653
IMPA:330606
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330615 BUMPTEST & CALIBRATION STATION, GALAXY GX2 CHARGING #10128639
IMPA:330615
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330636 BUMPTEST & CALIBRATION STATION, GALAXY GX2 CHARGING #10128635
IMPA:330636
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330639 GAS CALIBRATION MODEL RP 58LTR, MSA USA #10045035 EU #10053022
IMPA:330639
MTML UOM:PCE
Type Model RP with RFID Tag, 58 Liter - 500 psig/34,5 Bar, Approval: EN12205, U.S. DOT-39 and Canadian TC-39M, Content: 1,45 Vol% Methane, 15,0 Vol% Oxygen, 60 ppm Carbon Monoxide, 20 ppm Hydrogen Sulfide, Balance: Nitrogen
330660 BUMPTEST STATION DRAEGER, W/OUT GAS CYLINDER #8319131
IMPA:330660
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330667 BUMPTEST STATION DRAEGER, INCL. TEST GAS CYL. #8319130
IMPA:330667
MTML UOM:SET
An automated test system provides simple and intelligent testing and calibration of multigas detectors, driven by the most advanced technology available in any portable gas detector. The gas provided by the Bump Test Station flows through the dust and water filter to the sensor(s) confirming correct functionality of the gas detector ensuring compliance with country-specific requirements and regulations, standards, recommendations, etc. Once any gas detector is placed in this system, it can be tested, calibrated automatically.
330668 CALIBRATION & BUMP TEST X-DOCK, 5300 X-AM 125 #8321880
IMPA:330668
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
330669 CALIBRATION & BUMP TEST X-DOCK, 5300 PAC #8321881
IMPA:330669
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
330670 CALIBRATION & BUMP TEST X-DOCK, 6300 MASTER #8321900
IMPA:330670
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
330671 CALIBRATION & BUMP TEST X-DOCK, 6600 MASTER #8321901
IMPA:330671
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
330672 CALIBRATION & BUMP TEST X-DOCK, MODULE X-AM 125 #8321890
IMPA:330672
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
330673 CALIBRATION & BUMP TEST X-DOCK, MODULE X-AM 125+ #8321891
IMPA:330673
MTML UOM:SET
The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac gas detection instruments. Insert the device, close the lid and remove it when the indicator goes “green“ – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations. All Draeger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration.
© 2025 ShipServ Limited